Fluke922 Airflow Meter/Micromanometer

Previous 2 / 4 Next

Fluke922 Airflow Meter/Micromanometer FLUKE Air Tester Fluke922 Airflow Meter/Micromanometer FLUKE Air Tester Fluke922 Airflow Meter/Micromanometer FLUKE Air Tester


Today’s HVAC technicians want a simple solution for diagnosing ventilation issues. Differential pressure measurements only tell part of the story. Technicians also want to measure air velocity and flow, without having to resort to expensive, difficult to use, specialist tools. The Fluke 922 makes airflow measurements easy by combining three tools: differential pressure, airflow, and velocity into a single, rugged meter.

 

  • Measure pressure drops across key HVAC equipment to drive peak performance and extend equipment life
  • Match ventilation to occupant loads
  • Monitor indoor vs. outdoor pressure relationships and manage the building envelope
  • Promote indoor comfort and quality
  • Perform duct traversals for accurate airflow readings

Technical Specifications
Air Pressure
Range/Resolution/Accuracy  ± 4000 Pascals / 1 Pascal / ± 1 % + 1 Pascal
   ± 16 in H2O / 0.001 in H2O / ± 1 % + 0.01 in H2O
   ± 400 mm H2O / 0.1 mm H2O / ± 1 % + 0.1 mm H2O
   ± 40 mbar / 0.01 mbar / ± 1 % + 0.01 mbar
   ± 0.6 PSI / 0.0001 PSI / ± 1 % + 0.0001 PSI
Air Velocity
Range/Resolution/Accuracy  250 to 16,000 fpm / 1 fpm / ± 2.5 % of reading at 2000 fpm (10.00 m/s)
   1 to 80 m/s / 0.001 m/s / ± 2.5 % of reading at 2000 fpm (10.00 m/s)
Air Flow (Volume)
Range/Resolution/Accuracy  0 to 99,999 cfm / 1 cfm / Accuracy is a function of velocity and duct size
   0 to 99,999 / 1 m3/hr / Accuracy is a function of velocity and duct size
   0 to 99,999 l/s / 1 l/s / Accuracy is a function of velocity and duct size
Temperature
Range/Resolution/Accuracy  0 °C to 50 °C / ± 1 % + 2 °C / 0.1 °C
   32 °F to 122 °F / ± 1 % + 4 °F / 0.1 °F

 

General Specifications
Operating Temperature
   0 °C to +50 °C (+32 °F to +122 °F)
Storage Temperature
   -40 °C to +60 °C (-40 °F to +140 °F)
Relative Humidity
   0% to 90%, non-condensing
IP Rating
   IP40
Operating Altitude
   2000 m
Storage Altitude
   12000 m
EMI, RFI, EMC
   Meets requirements for EN61326-1
Vibration
   MIL-PREF-28800F, Class 3
Max Pressure at Each Port
   10 PSI
Data storage capacity
   99 readings
Warranty
   2 years
Power, battery life
   Four AA batteries
Battery Life
   280 hours without backlight, 60 hours with backlight

 
 

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version