VT04 Visual IR Thermometer Maintenance Combo Kit

Previous 3 / 16 Next

VT04 Visual IR Thermometer Maintenance Combo Kit FLUKE Thermometer VT04 Visual IR Thermometer Maintenance Combo Kit FLUKE Thermometer VT04 Visual IR Thermometer Maintenance Combo Kit FLUKE Thermometer


Fluke VT04 Visual IR Thermometer


Key Features
Built-in digital camera Yes
Thermal heat map overlay Yes, five blending modes
Image optics system PyroBlend® Plus optic *4x sharper image than VT02
Field of view 28° x 28°
Hi-Lo temperature alarms Yes
Time lapse image capture Yes
Auto-monitor alarm Yes
Battery type Li-Ion rechargeable
Training No training required
Ergonomics Slim pocket-sized design
Hot and cold markers Yes
General Features
Battery life Eight (8) hours
Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
Temperature measurement accuracy +/- 2 °C or +/- 2 %
Temperature measurement Yes, centerpoint
Storage medium (micro SD card) Stores up to 10,000 images per Gb (Four (4) Gb card included)
Infrared spectral band 6.5 μm to 14 μm
Level and span Auto
Focus mechanism Focus free, no training required with built-in intelligence
Focus options-exclusive user selectable NEAR/FAR options NEAR < 23 cm (9 in); FAR > 23 cm (9 in)
Dimensions 21 cm x 7.5 cm x 5.5 (8.3 in x 3 in x 2.2 in); < 350 g. (12.5 oz.)
File format .is2 format saved to SD card. User can create professional reports or export images in SmartView (BMP, DIB, GIF, SPE, FIF, SPEG, JPG, PNG, TIF and TIFF)
Safety and compliance CFR47: 2009 Class A. Part 15 subpart B; CE: EN 61326:2006; IEC/EN 61010-1:2010
Warranty Two (2) years

Fluke 1507/1503 Insulation Resistance Testers


AC/DC Voltage Measurement
Accuracy Range 600.0 V
Resolution 0.1 V
50 Hz to 400 Hz ± (% of Rdg + Digits) ± (2 % + 3)
Input impedance 3 MΩ (nominal), < 100 pF
Common mode rejection ratio (1 kΩ unbalanced) > 60 dB at dc, 50 or 60 Hz
Overload Protection 600 V rms or dc

 

Earth Bond Resistance Measurement
Range/Resolution 20.00 Ω 0.01 Ω
200.0 Ω 0.1 Ω
2000 Ω 1.0 Ω
20.00 kΩ 0.01 kΩ
Accuracy ± (1.5 % + 3)
Overload Protection 2 V rms or dc
Open Circuit Test Voltage > 4.0 V, < 8 V
Short circuit current > 200.0 mA

 

Insulation Specifications
Measurement range 1507 0.01 MΩ to 10 GΩ
1503 0.01 MΩ to 2000 MΩ
Test voltage 1507 50 V, 100 V, 250 V, 500 V, 1000 V
1503 500 V, 1000V
Test voltage accuracy + 20 %, - 0 %
Short circuit current 1 mA nominal
Auto discharge Discharge time < 0.5 second for C = 1 µF or less
Live circuit indicator Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive load Operable with up to 1 µF load
Measure accuracy 50 V ±(3 % + 5)
100 V ±(3 % + 5)
250 V ±(1.5 % + 5)
500 V ±(1.5 % + 5)
1000 V ±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ

 

General Specifications
Maximum voltage applied to any terminal 600 V ac rms or dc
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F)
Relative humidity 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F)
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F)
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Shock 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)
Electromagnetic compatibility In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)
Safety Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
Certifications CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
Batteries Four AA batteries (NEDA 15A or IEC LR6)
Battery life Insulation test use Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.
Size 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)
Weight 550 g (1.2 lb)
IP Rating IP40
Altitude Operating 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage) 12,000 m
Over-range capability 110 % of range
Included accessories TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe
 

Model Name Description
FLK-VT04-M-KIT Includes:
  • VT04 Visual IR Thermometer
  • 1507 Insulation Resistance Tester

Cases and Holsters
FLK-VT04-HARD CASE Hard case for visual IR thermometers

Batteries, Chargers and Adapters
FLK-VT04-Charger Replacement Charger for the Fluke VT04 Li-Ion Rechargeable Battery
FLK-VT04-Battery Replacement Li-ion rechargeable battery for the VT04

Cases and Holsters
C90 C90 soft case for DMMs and visual IR thermometers

Please leave your enquiry here, we will reply as soon as possible.