Fluke VT04 Visual IR Thermometer
Key Features |
Built-in digital camera |
Yes |
Thermal heat map overlay |
Yes, five blending modes |
Image optics system |
PyroBlend® Plus optic *4x sharper image than VT02 |
Field of view |
28° x 28° |
Hi-Lo temperature alarms |
Yes |
Time lapse image capture |
Yes |
Auto-monitor alarm |
Yes |
Battery type |
Li-Ion rechargeable |
Training |
No training required |
Ergonomics |
Slim pocket-sized design |
Hot and cold markers |
Yes |
General Features |
Battery life |
Eight (8) hours |
Temperature measurement range |
-10 °C to +250 °C (14 °F to 482 °F) |
Temperature measurement accuracy |
+/- 2 °C or +/- 2 % |
Temperature measurement |
Yes, centerpoint |
Storage medium (micro SD card) |
Stores up to 10,000 images per Gb (Four (4) Gb card included) |
Infrared spectral band |
6.5 μm to 14 μm |
Level and span |
Auto |
Focus mechanism |
Focus free, no training required with built-in intelligence |
Focus options-exclusive user selectable NEAR/FAR options |
NEAR < 23 cm (9 in); FAR > 23 cm (9 in) |
Dimensions |
21 cm x 7.5 cm x 5.5 (8.3 in x 3 in x 2.2 in); < 350 g. (12.5 oz.) |
File format |
.is2 format saved to SD card. User can create professional reports or export images in SmartView (BMP, DIB, GIF, SPE, FIF, SPEG, JPG, PNG, TIF and TIFF) |
Safety and compliance |
CFR47: 2009 Class A. Part 15 subpart B; CE: EN 61326:2006; IEC/EN 61010-1:2010 |
Warranty |
Two (2) years |
Fluke 1507/1503 Insulation Resistance Testers
AC/DC Voltage Measurement |
Accuracy |
Range |
600.0 V |
Resolution |
0.1 V |
50 Hz to 400 Hz ± (% of Rdg + Digits) |
± (2 % + 3) |
Input impedance |
3 MΩ (nominal), < 100 pF |
Common mode rejection ratio (1 kΩ unbalanced) |
> 60 dB at dc, 50 or 60 Hz |
Overload Protection |
600 V rms or dc |
Earth Bond Resistance Measurement |
Range/Resolution |
20.00 Ω |
0.01 Ω |
200.0 Ω |
0.1 Ω |
2000 Ω |
1.0 Ω |
20.00 kΩ |
0.01 kΩ |
Accuracy |
± (1.5 % + 3) |
Overload Protection |
2 V rms or dc |
Open Circuit Test Voltage |
> 4.0 V, < 8 V |
Short circuit current |
> 200.0 mA |
Insulation Specifications |
Measurement range |
1507 |
0.01 MΩ to 10 GΩ |
1503 |
0.01 MΩ to 2000 MΩ |
Test voltage |
1507 |
50 V, 100 V, 250 V, 500 V, 1000 V |
1503 |
500 V, 1000V |
Test voltage accuracy |
+ 20 %, - 0 % |
Short circuit current |
1 mA nominal |
Auto discharge |
Discharge time < 0.5 second for C = 1 µF or less |
Live circuit indicator |
Inhibit test if terminal voltage > 30 V prior to initialization of test |
Maximum capacitive load |
Operable with up to 1 µF load |
Measure accuracy |
50 V |
±(3 % + 5) |
100 V |
±(3 % + 5) |
250 V |
±(1.5 % + 5) |
500 V |
±(1.5 % + 5) |
1000 V |
±(1.5 % + 5) to 2000 MΩ, ±(10 % + 3) above 2000 MΩ |
General Specifications |
Maximum voltage applied to any terminal |
600 V ac rms or dc |
Storage temperature |
-40 °C to 60 °C (-40 °F to 140 °F) |
Operating temperature |
-20 °C to 55 °C (-4 °F to 131 °F) |
Temperature coefficient |
0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F) |
Relative humidity |
0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) |
0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) |
0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) |
Vibration |
Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument |
Shock |
1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor) |
Electromagnetic compatibility |
In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997) |
Safety |
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV) |
Certifications |
CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition |
Batteries |
Four AA batteries (NEDA 15A or IEC LR6) |
Battery life |
Insulation test use |
Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
Resistance measurements |
Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off. |
Size |
5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) |
Weight |
550 g (1.2 lb) |
IP Rating |
IP40 |
Altitude |
Operating |
2000 m CAT IV 600 V, 3000 m CAT III 600 V |
Non-operating (storage) |
12,000 m |
Over-range capability |
110 % of range |
Included accessories |
TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe |
|
|
|
|