VT04 Visual IR Thermometer Electrical Combo Kit

Previous 1 / 16 Next

VT04 Visual IR Thermometer Electrical Combo Kit FLUKE Thermometer


 

Fluke VT04 Visual IR Thermometer


Key Features
Built-in digital camera Yes
Thermal heat map overlay Yes, five blending modes
Image optics system PyroBlend® Plus optic *4x sharper image than VT02
Field of view 28° x 28°
Hi-Lo temperature alarms Yes
Time lapse image capture Yes
Auto-monitor alarm Yes
Battery type Li-Ion rechargeable
Training No training required
Ergonomics Slim pocket-sized design
Hot and cold markers Yes
General Features
Battery life Eight (8) hours
Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
Temperature measurement accuracy +/- 2 °C or +/- 2 %
Temperature measurement Yes, centerpoint
Storage medium (micro SD card) Stores up to 10,000 images per Gb (Four (4) Gb card included)
Infrared spectral band 6.5 μm to 14 μm
Level and span Auto
Focus mechanism Focus free, no training required with built-in intelligence
Focus options-exclusive user selectable NEAR/FAR options NEAR < 23 cm (9 in); FAR > 23 cm (9 in)
Dimensions 21 cm x 7.5 cm x 5.5 (8.3 in x 3 in x 2.2 in); < 350 g. (12.5 oz.)
File format .is2 format saved to SD card. User can create professional reports or export images in SmartView (BMP, DIB, GIF, SPE, FIF, SPEG, JPG, PNG, TIF and TIFF)
Safety and compliance CFR47: 2009 Class A. Part 15 subpart B; CE: EN 61326:2006; IEC/EN 61010-1:2010
Warranty Two (2) years

Fluke 376 Clamp Meter


Specifications
Diameter of measurable conductor 01.3 or 34 mm max
Operating temperature -14 to 122ºF (-10 to 50ºC)
Storage temperature -40 to 140ºF (-40 to 60ºC)
Operating humidity < 90% @ 10 to 30 ºC, < 75% @ 30 to 40ºC
Operating altitude 0 to 3000 m
Size 246 x 83 x 43 mm, (9.685 x 3.267 x 1.692 in.)
Weight 388g, (14 oz.)
Temperature coefficient 0.01% ºC
(<18ºC or > 28ºC)
Warranty Three years for electronics
One year for cable and clamp assembly

Fluke 117 Digital Multimeter


Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10 °C to + 50 °C
Storage temperature -40 °C to + 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life 400 hours typical, without backlight

 

Accuracy Specifications
DC millivolts Range/Resolution 600.0 mV / 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range/Resolution 600.0 V / 0.1 V
Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts¹ true-rms Range/Resolution 600.0 mV / 0.1 mV
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts¹ true-rms Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range/Resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of
500 μs or longer.
Ohms Range/Resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9 % + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5 % + 2
Diode test Range/Resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance Range/Resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/Resolution > 1000 μF
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
AC amps true-rms (45 Hz to 500 Hz) Range/Resolution 6.000 A / 0.1 A
10.00 A / 0.01 A
Accuracy 1.5% + 3
20 A continuous overload for 30 seconds max
DC amps Range/Resolution 6.000 A / 0.1 A10.00 A / 0.01 A
Accuracy 1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)² Range/Resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2

Notes:

  1. All AC voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
  2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
  3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
  4. Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F.


Mechanical and General Specifications
Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight 550 g
Warranty 3 years
 

Model Name Description
FLK-VT04-E-KIT Includes:
  • VT04 Visual IR Thermometer
  • 376 AC/DC True-rms Clamp Meter
  • 117 Electricians' Multimeter

Cases and Holsters
FLK-VT04-HARD CASE Hard case for visual IR thermometers

Batteries, Chargers and Adapters
FLK-VT04-Charger Replacement Charger for the Fluke VT04 Li-Ion Rechargeable Battery
FLK-VT04-Battery Replacement Li-ion rechargeable battery for the VT04

Cases and Holsters